banner products tws efen - logo trans

AC 690 V aR

With knife contacts acc. DIN 43620

  A
Size Amps Utilization category Order No. Pack
1 80 aR 35214.0010 3
100 aR 35214.0020 3
125 aR 35214.0030 3
160 aR 35214.0040 3
200 aR 35214.0050 3
250 aR 35214.0060 3
2 125 aR 35215.0010 3
160 aR 35215.0020 3
200 aR 35215.0030 3
250 aR 35215.0040 3
315 aR 35215.0050 3
350 aR 35215.0060 3
400 aR 35215.0070 3

 

With screw contacts (center to center distance 110 mm) acc. DIN 43653

  A
Size Amps Utilization category Order No. Pack
1 100 aR 35213.0010 3
125 aR 35213.0020 3
160 aR 35213.0030 3
200 aR 35213.0040 3
250 aR 35213.0050 3
315 aR 35213.0060 3
350 aR 35213.0070 3
400 aR 35213.0080 3
450 aR 35213.0090 3
500 aR 35213.0100 3

Dimensons: DIN 43620 Dimensions: DIN 43653
Dimensions-DIN 43620 Dimensions-DIN 43653

 

For protection of semiconductors – Pure silver fuse element

Time-current characteristics
Time-current characteristics For protection of semiconductors – Pure silver fuse element - AC 690 V aR
Cut-off current characteristics
Cut-off current characteristics For protection of semiconductors – Pure silver fuse element - AC 690 V aR
Prospective Short-Circuit Current symmetrical RMS

 

Technical Data

With knife contacts acc. DIN 43620

AC 690 V aR size 1 With knife
  Rated current Power dissipation
Pa/W
Min. Pre-arcing
I2t value
A2s
Maximum operating I2t value
A2s
Size In/A at 0,8 xln at ln   at AC 400 V at AC 500 V at AC 690 V
1 80 12,0 20 290 1300 1600 2200
100 14,4 24 570 2600 3200 4300
125 17,4 29 1000 4700 5800 7900
160 21,0 35 1900 8900 11000 15000
200 27,0 45 2900 14200 17500 24000
250 33,0 55 5300 24800 30400 42000
AC 690 V aR size 2 With knife
2 125 16,8 28 740 3900 5000 6800
160 22,2 37 1660 8200 10300 14100
200 25,2 42 2900 14000 17500 24000
250 33,6 56 4600 23000 28500 39200
315 39,0 65 9000 45300 55900 76800
350 42,6 71 11700 58200 72400 99500
400 49,8 83 16000 80500 99500 136500

 

With screw contacts (center to center distance 110 mm) acc. DIN 43653

AC 690 V aR size 1 With screw contacts
  Rated current Power dissipation
Pa/W
Min. Pre-arcing
I2t value
A2s
Maximum operating I2t value
A2s
Size In/A at 0,8 xln at ln   at AC 400 V at AC 500 V at AC 690 V
 1 100 13,8 23 420 1900 2400 3300
125 15,0 25 740 3400 4200 5800
160 21,0 35 1400 6400 8100 11000
200 24,0 40 2300 11200 14000 19000
250 25,8 43 4600 21200 26600 36000
315 28,8 48 8300 38300 48000 65000
350 32,4 54 11000 50700 63500 86000
400 39,0 65 15100 69600 87200 118000
450 41,4 69 21200 97900 122600 166000
500 46,8 78 26900 124400 155900 211000

 

Accessories

Blown fuse-monitoring

– May be used parallel to fuses for rectifier and in AC-/DC circuits.

Striker Bases

The striker bases are equipped with auxiliary switches

  • 1 NC and 1 NO (2 NO on demand)
  • Ue = 380 V / 125 V DC (with resistive load)
  • Ie = 010 A/ 00,5 A DC (with resistive load) with tab 6.3 according to DIN 46 248
  Dimensions    
Description a b c Order No. Pack
Base 690 V 129 42 40 33087.0010 5
Base 1000 V 148  61  40 33088.0010 5
Base 1200 V 213 72,5  70 33089.0010 4
Base 1500 V 194 72,5  70 33090.0010 4
Base 2000 V 233 107,5  70 33091.0010 4

 

Strikers

– Strikers operate parallel to NH fuse-links. Strikers are no fuselinks, meaning they have to be used in combination with NH fuse-links.
Strikers - AC 690 V aR
C = Pin operating distance mm

 

  Min. sensitiveness R Dimensions    
Description
V A Ω b c f l Order No. Pack
Striker
690 V 9 2,5 12 1 18 60±1 36000.0010 12
690 V / ≥ 2 V 2 7 10,3 1 18 60±1 36031.0020 12
1000 V 10 3 12,4 1 18 79±1 36001.0010 12
1200 V 48 2 18 36 17 100±3 36006.0010 30
1200 V 48 2 18 25 17 100±3 36007.0010 25
1500 V 48 2 18 8 20 116±1 36003.0010 15
1500 V with pin 48 2 18 8 20 11,5 116±1 36004.0010 25
2000 V 55 2,5 20 8 20 150±1 36002.0010 16
Contact clip for striker 51516.0100 1

 

elegard

The elegard blown fuse-monitoring can be used onto any standardized NH fuse-link with live gripping lugs size 00-4. An interchangeable striker unit is electrically connected with the live gripping lugs by spring contacts of the elegard holder. The NH fuse-link serves as carrier and when it operates, the elegard striker releases a pin, operating a micro switch.
Description Order No. Pack
elegard– Holder 36030.0000 4
elegard – Striker
690 V/> 9 V 36031.0010 12
690 V/≥ 2 V 36031.0020 12

Load monitoring case

EFEN load monitoring cases are available in 2 sizes

Load monitoring case
Size A suitable to carry each

– 3 current transformer fuse-links size 2
– 3 current transformers
– 3 maximum ammeters
– 3 retaining rings

Size B suitable to carry each

– 6 current transformer fuse-links size 2
– 3 current transformers
– 3 maximum ammeters
– 1 pliers for retaining rings for bores
– 6 retaining rings
– 1 handle with cuff

Description Order No. Pack
Load monitoring case A 85196.0100 1
Load monitoring case B 85263.0100 1

Micro switch AC 250 V 5 A
Micro switch AC 250 V 5 A
Flat connector DIN 46244 A2,8 x 0,5
Flat connector DIN 46244 A2,8 x 0,5
Change fuse-link only after removal of the elegard-holder
Change fuse-link only after removal of the elegard-holder

 

Current Metering by means of c.t.-fuse-link combination unit

Current transformer,
Maximum ammeter,
EFEN special Fuse-Link

Current transformers can be used together with the special EFEN NH fuse-links in a combination unit. Originally the main framing dimensions of the transformer fuse unit are not larger than those of an NH fuse-link acc. to DIN 43620/1. It was necessary to reduce the rated voltage from AC 500 V to AC 400 V. Breaking capacity, discrimination and characteristic gG unchanged and correspond to DIN/VDE 0636/201 and IEC 60269-2-1.

The current transformers has 2 pairs of sockets. It can permanently be operated unbridged as the idle voltage at the secondary with red maximum pointer has two ranges. Allowable permanent overload to 200 %.

Current Metering by means of c.t.-fuse-link combination unit
Size a1 b g n p q r
2 150 30 66 159 120 74 123
3 152 32 66 164 124 88 131

Description Size Meter range Order No.
Pack
Current transformer (fitting with special fuse link) 2 200-400/5 A 81142.0100 1
2 200-400/1 A 81142.0300 1
2 100-200/5 A 81152.0100 1
3 300-600/5 A 81153.0100 1
Maximum ammeter to be plugged onto the current transformer 2 200-400/5 A 85094.0100 1
2 200-400/1 A 85094.0300 1
2 100-200/5 A 85153.0100 1
3 300-600/5 A 85100.0100 1
Special fuse link AC 400 V 2 100 35067.0010 1
2 125 35067.0020 1
2 160 35067.0030 1
2 200 35067.0040 1
2 224 35067.0050 1
2 250 35067.0060 1
2 315 35067.0070 1
2 (355) 35067.0080 1
2 400 35067.0090 1

NH replacement handles

acc. to VDE 0680/4, DIN 43620/4, IEC 60269-2-1 for NH fuse-links and solid-links.

NH replacement handles
Description Order No. Pack
NH handle for NH fuse-links DIN 43620/1 + DIN VDE 0636-201, size 00-3 (fits size 4 as well)
with hand protection, without cuff 36020.0010 10
with leather cuff, total length 352 mm 36022.0010 3
Handle for NH fuse-links with 120 mm distance between gripping-lugs 36018.0010 4

 

Solid-links size 00-4a

Solid-links can be used with NH fuse-bases acc. to DIN 43620/3 + VDE 0636-201and with NH fuse-switches, horizontal and vertical design, of corresponding sizes.
 Solid-links size 00-4a - Metall gripping-lugs Solid-links size 00-4a - Insulated gripping-lugs
Metall gripping-lugs Insulated gripping-lugs
   A  V Dimensions Metal gripping-lugs   Pack insulated gripping-lugs  Pack
Size Amps Voltage a b c d g e Order No.   Order No.  
00 160 690 77 15 35 47 6 17 36008.0010 15  36139.0010 12
0 160 690 122,5 15 35 65 6 17 36009.0010 10 36140.0010 6
1 250 690 132,5 20 40 65 6 20 36010.0010 9 36141.0010 12
2 400 690 147,5 25 48 65 6 20 36011.0010 6 36142.0010 6
3 630 690 147,5 32 60 65 6 20 36012.0010 6 36143.0010 6
3 1000 690 147,5 32 60 65 6 20 36012.0020 6 36144.0010 6
3L 1000 1500 203 32 60 120 6 20 36015.0020 10
4 1250 690 200 50 85 65 8 25 36013.0010 10
4a 1600 690 200 50 85 87 6 25 36014.0010 6