banner products tws hager-logo trans

MCCBs and trip-free switches x160

Moulded case circuit breakers x160

Thermal magnetic trip unit, 2 versions:

– Z version: fixed thermal and fixed magnetic, collar terminal
– S version: adjustable thermal and fixed magnetic, cable lug terminal
– P version: fixed thermal and fixed magnetic, cable lug terminal 1P, 2P, 3P and 4P

Mechanical test button, lockable settings, integrated padlocking handle Ø 4mm (S version), needs accessory for DIN rail mounting.

Connection capacity

  • 95 mm2 rigid cables
  • 70 mm2 flexible cables

Comply with IEC 60 947-2.

Trip-free switches

  • Allows tripping at distance using a voltmetrical trip unit (optional) AC 22/23A.

Comply with IEC 60 947-3.

  Designation In Cat. Ref.
1P 2P 3P 4P
HDA125P MCCBs x160 18kA  16A HDA014Z HDA015P HDA016P HDA017P
breaking capacity  20A HDA018Z HDA019P HDA020P  HDA021P
Ics : 18 kA (400/415 V AC)  25A  HDA023Z  HDA024P  HDA025P  HDA026P
fixed thermal : 1x In  32A  HDA030Z  HDA031P  HDA032P  HDA033P
fixed magnetic : > 10 x In  40A  HDA038Z  HDA039P  HDA040P  HDA041P
 50A  HDA048Z  HDA049P  HDA050P HDA051P
 63A  HDA061Z  HDA062P  HDA063P  HDA064P
 80A  HDA078Z  HDA079P  HDA080P  HDA081P
HDA125P  100A  HDA098Z  HDA099P  HDA100P  HDA101P
 125A  HDA123Z HDA124P  HDA125P  HDA126P
 160A  –   HDA159P  HDA160P  HDA161P 
  
adjustable thermal :  25A  –  – HDA025S HDA026S
0,63 – 0,8 – 1 x In  40A  –  –  HDA040S  HDA041S
fixed magnetic : > 10 x In  63A  –  –  HDA063S  HDA064S
 80A  –  –  HDA080S  HDA081S
 100A  –  –  HDA100S  HDA101S
 125A  –  –  HDA125S  HDA126S
 160A  –  –  HDA160S  HDA161S
HDA161S MCCBs x160 25kA  16A HHA014Z HHA015P HHA016P HHA017P
breaking capacity  20A  HHA018Z  HHA019P  HHA020P  HHA021P
Ics : 20 kA (400/415 V AC)  25A HHA023Z  HHA024P HHA025P  HHA026P
fixed thermal : 1x In  32A  HHA030Z  HHA031P  HHA032P  HHA033P
fixed magnetic : > 10 x In  40A  HHA038Z  HHA039P  HHA040P  HHA041P
 50A  HHA048Z  HHA049P  HHA050P  HHA051P
 63A  HHA061Z  HHA062P HHA063P  HHA064P
 80A HHA078Z HHA079P HHA080P HHA081P
 100A HHA098Z HHA099P HHA100P HHA101P
 125A HHA123Z HHA124P HHA125P HHA126P
 HDA161S  160A  –  HHA159P  HHA160P  HHA161P
adjustable thermal : HHA025S  HHA026S
0,63 – 0,8 – 1 x In  –
HHA040S   HHA041S
fixed magnetic : > 10 x In  – HHA063S   HHA064S
 –  – HHA080S
HHA081S
 –  – HHA100S   HHA101S
 –  – HHA125S   HHA126S
 –  – HHA160S   HHA161S
HNA125P MCCBs x160 40kA 16A  –  –  HNA016P  HNA017P
breaking capacity  20A  –  –  HNA020P  HNA021P
Ics : 25 kA (400/415 V AC)  25A  –  –  HNA025P  HNA026P
fixed thermal : 1 x In  32A  –  –  HNA032P  HNA033P
fixed magnetic : > 10 x In  40A  –  –  HNA040P  HNA041P
 50A  –  –  HNA050P  HNA051P
 63A  –  – HNA063P HNA064P
 80A  –  –  HNA080P  HNA081P
 100A  –  –  HNA100P  HNA101P
 125A  –  –  HNA125P  HNA126P
 HNA125P  160A  –  –  HNA160P  HNA161P
adjustable thermal :  25A  –  – HNA025S HNA026S
0,63 – 0,8 – 1 x In  40A  –  –  HNA040S  HNA041S
fixed magnetic : > 10 x In  63A  –  –  HNA063S  HNA064S
 80A HNA080S HNA081S
 100A  –  –  HNA100S HNA101S
 125A  –  –  HNA125S  HNA126S
 160A  –  –  HNA160S  HNA161S
Trip-free switches x160  125A  –  – HCA125P HCA126P
suitable for AC22A / AC 23A  160A  –  –  HCA160P  HCA161P
Ue : 415 V AC
Icw (1s) : 2 kA

Accessories for MCCBs and trip-free switches x160

Indication contacts

– 1 changeover switch (ON/OFF): indicates the position of the MCCB is “open” or “close”.
– 1 changeover alarm contact: indicates MCCB tripping.

Coil connection

Connection capacity:

  • 0,75 mm2 flexible or rigid cables
  • Optional connection cables.
  • The cable capacity of the terminals is 0,5 to 1,25 mm2.

Shunt trip

  • Remotes tripping of MCCBs or trip-free switches.
  • Operating voltage: 0,7 to 1,1 x Un

Under voltage release

  • Allows the tripping of MCCBs or trip-free switches when voltage level drop between 35 and 70% of Un. Pick up voltage 0,85 x Un

Direct rotary handle
– padlockable
– equipped with front cover and handle
– fixing without any additional screw.

Extended rotary handle
– IP 55
– supplied complete with shaft and handle.

Designation Characteristics Cat. Ref.
HXA021H Auxiliary contacts 1 changeover contact (ON/OFF) HXA021H
AX 250 V AC / 3A
AL 125 V DC / 0,4A
1 NO + 1 NC
 HXA021H
HXA024H 1 changeover alarm contact HXA024H
250 V AC / 3A  
125 V DC / 0,4A
1 NO + 1 NC
Low level contact (ON/OFF)125 V HXA025H
AC1 NO + 1 NC
 HXA024H Low level alarm contact125 V  HXA026H
AC1 NO + 1 NC
Shunt trips 24 V DC HXA001H
SH 48 V DC HXA002H
100 – 120 V AC HXA003H
200 – 240 V AC HXA004H
380 – 450 V AC HXA005H
HXA014H Undervoltage releases 24 V DC HXA011H
UV 100 – 120 V AC HXA013H
200 – 240 V AC HXA014H
380 – 450 V AC HXA015H
 HXA014H
Delayed undervoltage releases 24 V DC HXA051H
DUVR 110 – 120 V AC HXA053H
220 – 240 V AC HXA054H
380 – 415 V AC HXA055H